SPLIT AIR CONDITIONER WALL MOUNTED TYPE OWNER'S MANUAL AGW52RH U.I./AGE52RH U.E. Thank you for choosing an Air Conditioner.Please read this OWNER'S MANUAL carefully prior to using, keep it for further reference.
CONTENTS P Contents ................................................................... 1 2 Safety Awareness.................................................................2 Name or Parts ......................................................................4 Operation procedure Remote Controller's Preparative Before Operation........................6 Operation Explanations of Air Conditioner.................................. 7 Service and Maintenance of the Air Conditioner.....................
SAFETY AWARENESS Read and understand thoroughly this safety awareness before use. The items indicated here are very important safety precautions, which must be followed. Must connect grounding line Absolutely no Must unplug plug Must be done WARNING Do not pull power cable. Hold plug to unplug when removing power, or part of the line in the power cable may break and cause fire. Do not let cool air blow directly at you for long time.Possible health problems may occur.
SAFETY AWARENESS WARNING Clean the air conditioner with a soft and dry cloth. Do not use chemical solvent,insecticide, Inflammable-spraying material or which damage the appearance of air conditioner for cleaning. The appliance shall be installed in accordance with national wiring regulations. The appliance must not be installed in the laundry. The appliance must be installed 2.3m above the floor.
NAME OF PARTS INDOOR UNIT Filter Front panel Air inlet Power supply cord SWING MANUAL Left / Right deflector Deflector OPERATION MODE OFF ON TIME CANCEL Display Remote controller I/O SET FAN SPEED SLEEP Manual operation (open the Front panel) Emergency operation switch Check switch Time indicator Sleep indicator Run indicator OUTDOOR UNIT Air inlet Connecting pipe Drain hose Air outlet Drain opening
NAME OF PARTS REMOTE CONTROLLER Signal ejecting window SWING BUTTON OPERATION DISPLAY MANUAL SWING BUTTON OPERATION MODE BUTTON TIME OFF BUTTON TIME ON BUTTON TEMPERATURE ADJUSTMNT BUTTON TIME CANCEL BUTTON RUN/STOP BUTTON TIME SET BUTTON FAN SPEED BUTTON SLEEP BUTTON RESET PIECE NOTICE cool only type hasn't HEAT mode 5
REMOTE CONTROLLER PREPARATION Open back cover, put in batteries. Short RESET piece with forceps. (Short two RESET piece after changing the batteries.) NOTICE • If the remote controller can't be operated normally, short two RESET piece, it will operate normally. • The signal can be reached within six metres directly in front of indoor unit. • Handle remote controller carefully. Do not drop, throw and get wetted. Avoid malfunction.
OPERATION OF AIR CONDITIONER Operation procedure-Control under the Remote controller 1 Run/Stop Press I/O button, start operation, and stop when repressed. 2 1 Temperature adjustment Press TEMPERATURE ADJUSTMENT button,decreases 1 C by press and increase 1 C by press button once. button once, Temperature change will display in the remote controller's display. 3 Fan speed adjustment Press FAN SPEED button,change the fan speed of indoor unit in the order of ( medium ) ( high ) ( auto ).
OPERATION OF AIR CONDITIONER 2 Press SWING button, the deflector start to opreate.. Change right/left air flow direction Manually swing Left/Right deflector,to change right/left air flow direction.Complete adjustment before operation, if adjusted during operation,the auto swinging deflector may pinch your fingers.(Fig. 1) ( Fig.1 ) ADVICE In DRY or COOL mode, advise to make the Fan speed with (auto), air blows downward in (1).
OPERATION OF AIR CONDITIONER 61 Operation mode adjustment Cool only type has not HEAT mode . 1 AUTO mode When started, operation mode will turn into COOL or DRY or HEAT mode as per room temperature, if operation stops for two hours, it restarts in the same mode set as before operation was stopped. Once operation mode is set,it will not be influenced even if room temperature has changed.Press MAUNAL SWING button or SWING button to change up/down air flow direction.
OPERATION OF AIR CONDITIONER 71 Timer operation Timer operation ON 1 Press button ON when air conditioner stops , of on the ¡flicker ± ¡ ±Remote Controller display. OFF Press button when air conditioner operates , Remote Controller display. 2 Press button ON OFF of ¡ ± flicker on ¡ ±the ON or to enter time setting . press button or the timer will increase 1 hour, the time will display on remote controller . 3 Press button to fix setting time . Remote Controller display.
SERVICE AND MAINTENANCE Air Conditioner no use for a long time. 1 Start fan only for 3-4 hours to completely dry the inside of the indoor unit. Set COOL mode or HEAT mode, and select the highest setting temperature, then fan turns. Want to use the Air Conditioner 1 ION ERAT Clean filters and replace them to original position.Clean indoor unit with soft clothe. Do not use gasoline, benzene, thinner, grinding powder, detergent,insecticide etc. to clean units as they can hurt the units.
SERVICE AND MAINTENANCE Deodorization filter, Air cleaner, Filters must be cleaned termly. Open front panel only after air conditioner stops completely. Filters should be cleaned once every two weeks. Clean deodorization filters and air cleaner. 1 Take out filters. 1 Take out filters first, then take out 2 Clean filters with a vacuum cleaner 2 Clean deodorization filter, air clean- 3 Clean filters with clean water, then 3 Clean filters with clean water, then or by typing them gently.
FAULT CONFIRMATION AND ANALYSIS If problems can not be corrected after doing below items, please stop the air conditioner, contact our air conditioner specially engaged service centre nearest to you to get help. Is there a fault ? Air conditioner does not operate at all. Remote controller is not available and does not display. It is not running after I/O button is pressed. Cooling and heating efficiency is not good.
FAULT CONFIRMATION AND ANALYSIS Is there a fault ? Indoor unit fan stops for about 10 minutes during heating. Fault analysis It is defrosting of the outdoor unit coil.It should complete this process in about 10 minutes at most.( It freezes when outdoor temperature is low and humidity is high. ) Issues cracking sounds The friction sounds caused by expansion and contraction of front panel resulting from temperature changes.
PERFORMANCE PARAMETERS Model Function Power Rated cooling/heating capacity (BTU) Standard input power (W) Standard input current(A) Air flow volume(m 3 /h) Dehumidifying capacity (L/h) Protection class Water-proof Climate type Refrigerant (R407C) charge amount(g) 18000BTU indoor outdoor heat pump type 230V ~, 50Hz 18100(cool)/19700(heat) 2010(cool)/2340(heat) 9.8(cool)/10.6(heat) 750 2.5 I IP20(Indoor) IP24(Outdoor) T1 2000 Net weight (Kg) 43 14.
INSTALLATION SKETCH Installation sketch 105m m above 155mm above 24mm above Confirm installation place with the marker of indoor unit installation board. 1 2 3 4 Notice:do not put the drain hose high. G above 7mm 7 H F C B D Configuring pipe can be installed to back, right, underside, or left-back side. front back right left back underside left-back above 100mm 6 5 abov e 10 Cover connecting pipe with heat-isolating material.
INSTALLATION ACCESSORIES Before installation, inspect the following accessories: Indoor unit accessories Quantity Installation accessories Quantity 1 A Connecting pipe screws 4 5 B Bonding tape 1 Expansion rubber plug 5 C Clamp 3 4 Expansion bolt 2 D Cement nail 5 5 Battery 2 E Drain hose 2 6 Remote controller 1 F Opening cap 1 7 Felt 1 G Wall-hole cover 1 8 Adiabatic underlay 1 H Indoor wall-hole cover 1 9 connecting cable+signal wire 1+1 I putty 1 10 D
INSTALLATION INDOOR UNIT 1 Secure the mounting plate The mounting plate should be attached to the structural part of wall (post etc.). fasten string at the central hole at least 60mm 245mm or more from sidewall 175mm or more from sidewall mounting plate The holes at solid arrow position must be secured to avoid the shake of mounting plate. When the expansion bolts are used, two holes ( 11 20 or 11 26 ) that the distance between them is 450mm should be adopted.
INSTALLATION 41 Installation drain hose liquid pipe 1 NOTE: The drain hose must be arranged beneath the copper pipe. The drain hose must not be hunched or bended. Do not wrap the drain hose by pulling it. When the drain hose must be through the house, it should be wrapped by the special heat insulated materials. The copper pipe and the drain hose must be wrapped by felt strip. Heat insulated pad should be used in the place that the pipe contact the wall.
INSTALLATION 71 Seal of wall hole and fasten of pipe Use putty to seal the wall hole. Use clamp ( pipe fastener ) to secure the pipe at specified position.
31 Discharge the air procedure Connect assembly pipe to the appropriate valve on the indoor unit and outdoor unit and tighten the flare nut(as fig.1). Screw down the nut of connecting pipr with wrench(the torque as follow diagram ) (Fig.1) NOTICE 1.The number of bent position of the pipe in the indoor unit should not exceed 10. 2.The number of bent position of the pipe in the indoor unit and the outdoor unit should not exceed 15. 3. The radius of bent position should more than 10cm.
INSTALLATION 41 Add refrigerant If the connecting pipe is longer than 7 meters, add refrigerant as needed. (Cool only type) add amount A= (Lm-7m) 15g/m ; (Heat pump type)add amount A= (Lm-7m) 50g/m. (A: add refrigerant amount , L: the length of connecting pipe) the length of connecting pipe (m) 7 8 9 10 15 (Cool only type)add amount (g) 0 15 30 45 120 (Heat pump type)add amount (g) 0 50 100 150 450 The limit of tubing length is 15 and the limit of elevation difference is 7m.
Via Varese,90 21013 Gallarate(VA) Italy Phone:+39 0331 755 111 Fax:+39 0331 766 240 www.argoclima.