Hydraulic Brakes
General
Although the hydraulic brake system is self adjusting, the following require periodic attention:
Brake Fluid Level (Steering Brake Master Cylinders)
After every 50 hours of operation, check the brake uid level by removing the master
cylinder covers.
IMPORTANT
Thoroughly clean the master cylinder cover and surrounding area before removal.
The master cylinders are mounted tilted slightly back. When adding uid, ll until the
shallowest end of the uid level in the well is approximately 1/2" from the top lip of the
master cylinder. Figure 1
If the brake uid is below this level:
1. Add only fresh clean SILICONE - DOT
5 BRAKE FLUID (ARGO Part No.
126-19) to the correct level.
2. Replace the cover on each master cyl-
inder, making sure the rubber gaskets
are properly seated before tightening
the cover screws. Tighten snug by hand
only.
CAUTION
Do not overll the brake master cylinders.
Overlling can cause seal damage.
Use only SILICONE - DOT5 BRAKE FLU-
ID. Other brake uid is not compatible with
ARGO brake components and operating
temperatures. Use of other uids will void
the warranty and may cause loss of brakes
or steering.
Figure 1