Operation Manual

24
EG
When Emix Tank unit is correctly connected and electrically powered the RED LED is ON (stand by).
Power ON / OFF of Emix Tank
To switch on Emix Tank, push and hold the BUTTON for about 4 seconds until the RED LED turns off and the GREEN
LEDs of water temperature light up. Emix Tank unit is designed to be always ON.
To switch off Emix Tank, push and hold the BUTTON for about 4 seconds until the GREEN LEDs turn off and only the RED
LED stays on. At this point release the BUTTON.
Once turned on, Emix Tank unit displays the temperature inside the tank.
Desired temperature setting (setpoint)
Press and quickly release repeatedly the BUTTON until the led corresponding to the desired temperature lights up (see
table). After 5 seconds without any operation, Emix Tank exits the desired temperature setting procedure and begins to
display the water temperature in the tank.
Super Booster mode activation
When the Super Booster mode is activated, all the electrical heaters will be activated at the same time, together with the
heat pump.
When the setpoint is reached, all electrical heaters are switched off and the Super Booster mode is automatically turned
off.
To activate the Super Booster mode, press and hold the BUTTON until the BLUE LED lights up.
At this point release BUTTON.
3 consecutive beeps con rm the setting.
To deactivate the Super Booster mode, press and hold the BUTTON until the GREEN LEDs turn off and the BLUE LED
lights up. At this point release BUTTON.
3 consecutive beeps con rm the deactivation.
HOW TO USE EMIX TANK
NOTE
By default, the Booster mode is off.
NOTE
By default, the Super Booster mode is off.
EMIX TANK CONFIGURATION
When Emix Tank is on, you can change the setting of some parameters.
To enter the con guration menu, press and hold the BUTTON until the BLUE, YELLOW and RED LEDs light up contem-
porary. At this point release the BUTTON.
After 5 seconds without any operation, Emix Tank exits the con guration procedure and returns to the previous menu.
Booster mode setting
The use of electrical heating elements installed in the storage tank allows you to heat the cold water faster and to reach
the desired water temperature even in conditions of very low external temperatures.
When you activate the Booster mode, the software will automatically handle the electrical heaters.
If after 120‘ from start up of the system the water setpoint is not reached, the  rst electrical element is automatically
activated. The second element will be activated after 120‘ following the course of the water temperature, until reaching
the setpoint.
To activate / deactivate the Booster mode, enter the con guration menu, then quickly press the BUTTON until the only
BLUE LED is  ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.