Setpoint limit setting with Heat Pump
It is possible to set the maximum achievable setpoint only with the Heat Pump. This limit can be set to 50°C or 58°C.
To change the setting, enter the con guration menu, then quickly press the BUTTON until the BLUE and YELLOW LEDs
are ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
NOTE
By default the limit is set to 50°C. We recommend to keep this setting to optimize the energy ef ciency of Emix Tank.
Antilegionella cycle setting
To activate / deactivate the Antilegionella cycle, enter the con guration menu, then quickly press the BUTTON until the
only YELLOW LED is ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
NOTE
By default, the Antilegionella cycle is on. If the cycle is turned off, the MANUFACTURER can not be held responsible.
For details on the operation of the Antilegionella cycle, see section “ANTILEGIONELLA CYCLE”.
Temperature delta setting for restart of the heat pump
When the water temperature reaches the set value or the maximum achievable value with the heat pump alone (in the
case of Emix Tank operation without other indoor units), the heat pump switches off and starts up again only when the
water temperature drops below the desired temperature of a certain value (delta).
You can change the startup delta of the heat pump by setting it to 5°C or 10°C.
To change the set value, enter the con guration menu, then quickly press the BUTTON until the BLUE and RED LEDs
are ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
NOTE
By default the startup delta of the heat pump is set to 10°C. We recommend to keep this setting to optimize the energy
ef ciency of Emix Tank.
Reset of the factory settings
To reset all the factory settings, enter the con guration menu, then quickly press the BUTTON until the BLUE, YELLOW
and RED LEDs are ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the reset of factory settings.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
Stratifi cation sensor selection
Emix Tank measures the water temperature in the tank through one of the two strati cation sensors.
It is possible to select which of the two sensors is read for the measurement.
To change the sensor, enter the con guration menu, then quickly press the BUTTON until the YELLOW and RED LEDs
are ashing.
Then wait a few seconds until all the 5 GREEN LEDs light up and press the BUTTON once more.
3 consecutive beeps con rm the setting.
If the button is not pressed, after a few seconds the display will return to the main menu without making any setting.
NOTE
By default the selected strati cation sensor is the upper one.