Installation Instructions

7
3 - INSTALLATION
3.1 - LOCATION
Protection index of the unit: IP 21.
Select the location for the unit on the basis of the following criteria
:
- the unit must be installed in a sheltered location,
- the unit must not be installed near the following:
. sources of heat,
. combustible materials,
. return / air intake of an adjacent building.
- it is necessary to make sure that the free space around the unit is
provided (see the minimum dimensions on the drawing opposite),
- installation must be simple and make maintenance work easy,
- the unit must be secured to a wall able to support its weight.
3.2 - MOUNTING THE UNIT
Remove the cover from the unit:
- remove the retaining screws (1 on each side and 1 on top) (1).
Slide the cover upward (2), until the bottom edge of the covers is aligned
with the lower part of the rear support, then pull it towards you (3).
Secure the unit to the wall. Refer to the position of the 4
mounting holes in the diagram opposite.
Use anchors and screws (not included) that are adapted
to the weight of the unit and the type of wall.
- Install the 2 screws in place in the upper holes (A) in
the wall.
- Hook the unit in place.
- Install the 2 screws in place in the lower holes (B).
0.80 m
0.20 m
0.20 m
1 m
3
A
B
Z
X
Y
Minimum clearance in front of the unit: 1 m
1
1
1
2
Align the bottom edge of the cover with the
lower part of the rear support
GB
X (mm) Y (mm) Z (mm)
HKBE
HKCE
HKDE
460
360 800