USER AND INSTALLATION MANUAL Single-Split Air Conditioner WALL 9000 WALL 12000 WALL 18000 Please read this manual carefully before installing and using the air conditioner, and retain for future reference.
Contents Information for use Precautions for use Description of components 3 4 Guide to the remote control and display Remote control buttons Getting to know the display icons Getting to know the remote control buttons Getting to know the button combination functions Operating guide Replacing the remote control batteries Emergency operation 5 5 5 7 8 8 9 Maintenance Care and cleaning 9 Troubleshooting Possible faults and solutions Analyzing faults and solutions 10 12 Installation instructions Instal
INFORMATION FOR USE Precautions for use WARNING • This product is not a toy. Children should be properly supervised to ensure that they do not play with the appliance. • This appliance should not be used by children under 8 years old or by persons with reduced physical, sensory or mental capabilities or lacking the necessary experience and knowledge, unless under supervision or given the necessary training concerning the use of the appliance by someone responsible for their safety.
Description of components Indoor unit Outdoor unit V 11/15 4
GUIDE TO THE REMOTE CONTROL AND DISPLAY Remote control buttons 1. ON/OFF button 2. MODE button 3. +/- button 4. FAN button 5. SWING button 6. SLEEP button 7. TIMER button Getting to know the display icons Timer on Timer OFF Signal receiver AUTO mode SWING mode COOL mode SLEEP mode DRY mode LOCK mode FAN mode SPEED mode HEAT mode Termperature settings Timer settings Getting to know the remote control buttons N.B.
• When you press the ON/OFF button on the remote control, the icon on the remote control display will flash once and the air conditioner will emit a beep. This means that the signal has been sent to the unit. • When the unit is off, the temperature will be shown on the remote control, the correspondent icon will appear. If the unit is on, you will see the icon of the correspondent mode. 1. ON/OFF button Press the ON/OFF button to turn the air conditioner on or off. 2.
. TIMER mode When the unit is on, press this button to set the timer to turn off the unit. T-OFF and H will light. Within 5 seconds, press the + or – button to turn off the timer. If you press the + or - button once, the timer will increase or decrease by 0.5 h. If you press the + or - button for 2 seconds, the time will change quickly. Release the button after the set time required is reached. Then press the TIMER button to confirm. The T-OFF and H icons will turn off.
Operating guide 1. When you connect the power, press the "ON/OFF" button on the remote control to turn the air conditioner on. Press the MODE button to select the desired operating mode: AUTO, COOL, DRY, FAN or HEAT. Press "+" or "-" to adjust the desired temperature. (The temperature cannot be adjusted in automatic mode.) Press the "FAN" button to set the desired fan speed: automatic, low, medium or high. Press the "SWING" button to adjust the fan's angle of airflow. 2. 3. 4. 5.
Emergency operation In the event of loss or failure of the remote control, use the emergency button located under the indoor unit's front panel to turn the air conditioner on or off. The unit will operate in automatic mode on start-up. Use isolated objects to press the AUTO button. pannellino pannellino tastoausiliario tasto ausiliario panel auxiliary button MAINTENANCE Care and cleaning N.B.: Disconnect the power before servicing or cleaning the unit.
• WARNING! When you remove the filters, avoid contact with the heat exchanger (there is a risk of cuts or abrasion). Do not use a hairdryer to dry the filters; the heat can cause damage and warping. Before-use checks 1. 2. 3. 4. Check that the air inlet and outlet are free of obstructions. Check that the circuit breaker, plug and socket are in good working order. Check that the filters are clean. Check that the outdoor unit's support bracket is not damaged or corroded.
correct? 4. Fault Check The indoor unit's Is the indoor temperature and humidity high? air outlet produces a mist Is the unit operating in automatic mode? The set temperature cannot be adjusted Does the desired temperature fall outside the available temperature range? Is the voltage too low? The desired level Is the filter dirty? of heating/cooling Does the set temperature fall within the cannot be available temperature range? achieved Are there any doors or windows open? Is there an odour source (e.g.
Analysing faults and solutions Error codes In the event of a fault, the temperature indicator on the indoor unit will flash to display the corresponding error code. Refer to the following list to identify the error code. Error code Faults and solutions E5 Can be eliminated by turning the unit off and on again. Otherwise, contact a qualified technician for assistance. E8 Can be eliminated by turning the unit off and on again. Otherwise, contact a qualified technician for assistance.
Almeno 15 cm Distanza dal soffitto INSTALLATION INSTRUCTIONS Installation diagrams Distanza dalla parete Almeno 15 cm Almeno 15 cm z ll'o s ion e Almeno 30 Distanza da Dis tan Distanza dal soffitto Almeno 15 cm Distanza dalla parete V 11/15 Almeno 250 cm tan a ad z tru m Distanza dall'ostruzione Dis en 0c Almeno 50 cm Alm 0 o3 Distanza dal pavimento Distanza dalla parete e za zion n a u tr st Di ll'os no da me m l A c 30 Tubo di scarico cm lla parete e ion 0 cm z u 20 str ll'o
Almeno 15 cm Distanza dalla parete Almeno 15 cm Distanza dall’ostruzione Almeno 300 cm Distanza dal pavimento Almeno 250 cm Distanza dall’ostruzione Almeno 50 cm Distanza dall’ostruzione Almeno 30 cm Distanza dalla parete Almeno 30 cm Distanza dall’ostruzione Almeno 200 cm Tubo di scarico Distanza dall’ostruzione Almeno 50 cm At least 15 cm Distance from wall At least 15 cm Distance from obstruction At least 300 cm Distance from floor At least 250 cm Distance from obstruction At least 50 cm Distance from o
Outdoor unit 1. Choose a location where the noise and airflow produced by the outdoor unit will not annoy neighbours. 2. The location should be well ventilated and dry; the outdoor unit must not be exposed to direct sunlight or strong winds. 3. The site should be able to support the weight of the outdoor unit. 4. Check that the installation complies with the requirements of the dimensional drawing for installation. 5. Choose a location out of the reach of children and away from animals or plants.
INSTALLATION Indoor unit installation Decide where to install the unit based on room design, architectural limitations and customer requirements. Check that in the selected location the unit can be accessed for servicing and cleaning the filters. To install, use the installation plate as a template to identify the exact position for the wall plugs and through-hole in the wall. The plastic casing has stoppers which if necessary can be removed to route the refrigerant lines and cables.
Step four: outlet pipe The pipe can be brought out in various different directions: right, rear right, left or rear left. Once you have selected the direction of the outlet (left or right), drill the corresponding hole at the bottom.
Step six: install the condensate drain pipe Connect the drain pipe to the outlet pipe of the indoor unit. Bind the joint with tape. tubo di scarico tubo d'uscita tubo di uscita nastro tubo di scarico tubo di scarico tubo isolante N.B.: • Add an insulating tube to the indoor drain pipe to prevent condensation. • The plastic wall plugs are not supplied. tuboisolante tubo di uscita tubo di scarico nastro insulating tube outlet pipe drain pipe tape Step seven: connect the indoor unit electrical cable 1.
N.B.: • All wiring must be connected as shown on the unit's wiring diagram. All indoor and outdoor unit cables must be connected by a qualified technician. • If the power cable is not long enough, contact the supplier for a new one. Do not attempt to extend it yourself. • For air conditioners equipped with a plug, the plug must be easily accessible upon completion of installation. • For air conditioners without a plug, install a circuit breaker on the line.
N.B.: • Avoid bending the drain pipe too much in order to prevent clogging. Outdoor unit installation Step one: secure the outdoor unit support 1. Choose a location for the unit according to the structure of the house. 2. Use expansion screws to secure the outdoor unit support in the chosen position. N.B.: • Take the appropriate safety measures when installing the outdoor unit. • Make sure that the bracket can support at least four times the weight of the unit.
2. Remove the screw cap of the valve and 4. Tighten the union nut with the wrench position the pipe joint in the bellmouth of the according to the following table. pipe. Hex nut diameter Tightening torque tubo del liquido (Nm) valvola del liquido tubo del gas valvola del gas valvola del liquido tubo del liquido tubo del gas valvola del gas 6.35 15 – 20 9.52 30 – 40 12.7 45 – 55 15.88 60 – 65 liquid valve liquid pipe gas pipe gas valve Step five: connect the outdoor electrical cable 1.
• Slant the drain pipe slightly downwards. The N.B.: • The height of the drain pipe through the wall drain pipe must not be bent, raised, twisted, etc. must not be greater than the height of the hole for the indoor unit's outlet pipe. Il tubo di scarico non deve salire verso l'alto Il tubo di scarico non deve salire verso l’alto The drain pipe must not go upwards • To ensure uniform drainage, the water outlet must not be placed in water.
Check for leaks using a leak detector. If you do not have a leak detector you can use soapy water. Post-installation checks Checks Has the unit been installed securely? Possible fault Is the thermal insulation of the pipes sufficient? The unit could fall, move or produce excessive noise. Risk of condensation and dripping water. Does the water drain properly? Risk of condensation and dripping water.
APPENDICES Piping configuration 1. Standard connecting tube length:5 m. 2. Minimum connecting tube length: 3 m. 3. Maximum connecting tube length and maximum height difference: Capacity Maximum connecting tube length Maximum height difference 9000Btu/h 15 10 12000Btu/h 20 10 18000Btu/h 20 10 Warning! Note the additional charge on the data plate affixed to the outdoor unit.
tubo allargatubi tagliatubi inclinato tubo irregolare sbavatura allargatubi forma dura tubo tubo tagliatubi inclinato irregolare sbavatura pipe expander hard mould pipe N.B.: • "A" varies according to diameter: pipe pipe cutter slanted uneven burred A (mm) Outdoor diameter (mm) 2. Remove burrs • Remove burrs with a file, ensuring they do not go into the pipe. Max. tubo limatrice verso il basso tubo limatrice verso il basso forma dura pipe file downwards 3. Secure an insulating tube Min.
V 11/15 26
REGULATION (EU) No. 517/2014 - F-GAS The unit contains R410A, a fluorinated greenhouse gas with global warming potential (GWP) = 2087.50. Do not release R410A into the atmosphere. www.argoclima.