Operation Manual

V 11/15
21
2. Remove the screw cap of the valve and
position the pipe joint in the bellmouth of the
pipe.
tubo del gas
tubo del liquido
valvola
del liquido
valvola del gas
4. Tighten the union nut with the wrench
according to the following table.
Hex nut diameter Tightening torque
(Nm)
6.35
15 – 20
9.52
30 – 40
12.7
45 – 55
15.88
60 – 65
valvola del liquido liquid valve
tubo del liquido liquid pipe
tubo del gas gas pipe
valvola del gas gas valve
Step five: connect the outdoor electrical cable
1. Remove the wire clip. Connect the power cable and the signal control cable (only for cooling and
heating units) to the wiring terminal according to colour. Secure them with the screws.
2. Secure the power cable and the signal control cable with the clip (only for cooling and heating
units).
N.B.: • Once you have tightened the screw, pull on the power cable gently to check it is secure.
• Never cut the power cable to extend or reduce the distance.
Step six: tidy up the pipes
1. The pipes should be routed along the wall,
bent only as much as is necessary and, if
possible, hidden from view. Minimum pipe
bending radius: 10 cm.
2. If the outdoor unit is higher than the hole in
the wall, you must create a U-bend in the pipe
before it enters the room to prevent rain from
getting into the room.
curva a U
parete
tubo di scarico
parete wall
curva a U U-bend
tubo di scarico drain pipe