Operating Instructions and Installation Instructions
V 03/17
55
sinistra
posteriore
sinistra
destra
posteriore
destra
destra right
posterioredestra rearright
sinistra left
posterioresinistra rearleft
foro da
praticare
sinistra
destra
destra right
forodapraticare holetobedrilled
sinistra left
Step five: connect the indoor unit pipe
Position the pipe joint in the corresponding
bellmouth.
Pre-tighten the union nut by hand.
dado raccordogiunto tubo
tubo
giunto pipe
tubo joint
dado union
raccordo nut
Adjust the torque according to the following table. Position the open-end spanner on the pipe joint
and position the torque wrench on the union nut. Tighten the nut with the wrench.
chiave
dinamometrica
chiave
a forchetta
tubo interno
tubo
dado raccordo
chiaveaforchetta open‐endspanner
chiavedinamometrica wrench
tubointerno innerpipe
dadoraccordo unionnut
tubo pipe
Hex nut diameter Tightening torque (Nm)
6.35
15 – 20
9.52
35 – 40
tubo isolante
tuboisolante insulatingtube
Wrap the indoor pipe and the joint of the
connecting pipe with an insulating tube. Then
wrap with tape.
Step six: install the condensate drain pipe
Connect the drain pipe to the outlet pipe of the
indoor unit.
Bind the joint with tape.
tuboisolante insulatingtube
tubo di scarico
nastro
tubo d'uscita
tubo di
uscita
tubo di scarico
tubo di scarico
tubo isolante