Otherwise, it may result in fire or
electric shock.
Otherwise, the accumulation of
dust can cause overheating.
Otherwise, it may cause
overheating or fire.
When cleaning the unit, stop
operation and turn off the
power.
Interrompere
l'alimentazione
elettrica.
Otherwise, may occur electric
shock or damage.
The voltage rating of this
product is 220 - 240V, 50Hz.
The compressor vibrates
strongly if the voltage is too low,
causing damage to the cooling
system. The electrical
components are easily
damaged if the voltage is too
high.
Do not attempt to repair the air
conditioner yourself.
An improper repair can cause
fire or electric shock. For this
reason, it is advisable to
contact a service center for
repairs.
Check if the installed media is
sufficiently stable.
If damaged, it can cause the
equipment to fall and cause injury.
Do not climb on the outdoor unit
or place anything on it.
The falling of the outdoor unit
can be dangerous
Earthing: The unit must be
properly grounded. The cable
grounding must be connected
with the appropriate device in
the building.
Operating limits
Indoor B.S./B.U.(°C) Outdoor B.S./B.U.(°C)
Max cooling temperature 32/23 43/26
Max heating temperature 27/- 24/18
Operating range:
Cooling mode: from -15°C to +43°C (outdoor temperature)
Heating mode: from -20°C to +24°C (outdoor temperature)