User`s manual
29
Note: The FEED button does not make the printer cut. For
cutting to occur when the panel setting is properly
enabled.
18
Cutter
30
Configuration
This section discusses calibration, printing configuration and
resetting the printer to factory defaults.
Performing Calibration
After the media is loaded, recommend you performing media
calibration to calibrate the label sensor.
1. Turn off the printer
2. Press and hold the PAUSE button and turn on the power.
3. When “CALIBRATION …” is displayed on the LCD (X-2000v,
X-3000v), and both READY and MEDIA indicators blink,
release the PAUSE button.
4. The printer feeds 12-inches of blank labels.
5. When “READY” is displayed, the READY and MEDIA
indicators stop blinking but remain illuminated.
Note: For X-1000v, the step3 will be bypassed.
Important! Recommend you performing media calibration after
changing media. Failure to do so could result in
improper detection by the label sensor.