User`s manual

89
4. Connect the dispenser sensor to JP15 (PEELER) on the
printer’s main board and secure the dispenser board in the
case.
5. Install the ribbon and media.
Screw
Dispenser
board
90
6. Turn on the printer.
7. For the X-2000v/X-3000v models set the parameter of
“DISPENSER INSTALLED” on the LCD to the ON position.
For the X-1000v bypass this step.
Calibrating the Dispenser Sensor
If you find the sensor is not sensitive enough or is having problems
detecting, you can use the following two commands to calibrate it.
Command ASCII Binary Remark
Set sensor
without label
<ESC>$R0 1BH 24H 52H 30H Command 0
Set sensor
with label
<ESC>$R1 1BH 24H 52H 31H Command 1
Calibration Steps
Step 1 Move the label away from the sensor, send command 0 and
wait for 2 seconds.
Step 2 Move a label under the sensor (10 mm below), hold it, send
command 1 and wait for 2 more seconds.