15.2 The L1 Status of a PRI Access
The ARGUS displays the Layer 1 alarms and messages, which provide detailed
information regarding the state of the PRI access and the transmission line (For further
information, see the CCITT/ITU guidelines G.703 and G.704).
The ARGUS in its Main menu
The ARGUS displays the time that has elapsed since
the ARGUS was initially started or it was last reset in
minutes and seconds (05:18).
The measurement time and all Layer 1 alarms and
messages are updated continuously.
Use the cursor keys to scroll.
< X > The PRI relay for the Rx/Tx pin
assignment will be toggled to its other
position, regardless of the state that it
was in before.
This function is only available with the L1
status menu, if there is currently no
signal. The state of the relay will remain
unchanged when you close the L1 status
menu.
Wires = means that Rx/Tx are normal
Wires X means that Rx/Tx are
inverted
<RESET> Reset the History function and all
counters.
<SAVE> Save the results (see page 102)
OK symbol: +
Error symbol: -
History symbol: ! This indicates that, regardless of the current state of the
access (+ or -), an error occurred during the test period.