16 Settings
The ARGUS can be configured to suit your special requirements. The default (factory)
settings can be restored by selecting “Reset” (see page 134 Reset).
16.1 PC/Trace
The ARGUS remains active and either saves the data from the D-channel (all of the D-
channel messages sent to and received from the network) in its internal Flash memory or
passes the data directly to the connected PC. The Remote function is optional.
The ARGUS in its Main menu
If the ARGUS cannot send the data to the PC without
errors, the PC/Trace” LED will flash at 5Hz (5 times per
sec).
The currently active settings will be marked in the display
with a .
The D-channel data saved in the Flash memory can be transferred to the PC in
the “Recorder” mode (see “BRI / PRI Recorder” on page 46.).
Auto PC sync. The D-channel data will be
sent to the PC.
Even after it is switched on
again, the ARGUS remains
in Trace mode and passes
D-channel data to the PC
(“PC/Trace” LED flashes).
Manual PC sync. The D-channel data will be
sent to the PC (“PC/Trace”
will flash).
When the ARGUS is
switched off and then back
on again, Trace mode will
be off.
Recording The D-channel data is
stored in the internal Flash
memory (the “PC/Trace”
LED flashes slowly)
Select Trace mode
Confirm the entry