Operation Manual

ARGUS
A
RGUS 125 145
D) ARGUS Error Messages
Error
Number
Error
Class
Cause Description
0 E Network The network is not in a state defined for DSS1 or 1TR6. It may
be that this state is normal for a PBX.
1 to 127 B,C,D,E Network DSS1 or 1TR6 causes
150 E ARGUS An error occurred during the supplementary service test.
Frequent cause: no response from network
152 B ARGUS The CF-Test was started with the wrong own number.
153 E ARGUS No HOLD is available, but HOLD is required to test the
supplementary service (ECT, 3pty)
154 E ARGUS CLIR or COLR could not be tested, since CLIP or COLP is not
available
161 B ARGUS The party called did not answer within the prescribed time
(approx.10 sec)
162 B ARGUS A call was setup to a remote subscriber, instead of being setup –
as was expected – to your own number.
163 E ARGUS The Auto-Test could not setup a connection and therefore the
AOC/D supplementary service could not be tested.
170 ARGUS During the Suppl.services test, a call came in without a B-
channel (call waiting). Therefore, it was not possible to accept
the call and test.
199 B ARGUS A call number was entered.
200 ARGUS Internal error
201 A ARGUS Network did not confirm acceptance of the call (CONN sent, no
CONN_ACK received from network)
204 A ARGUS - Layer 2 connection was cleared-down
- No response to SETUP (call setup)
- Layer 2 connection could not be setup
205 A ARGUS Reestablish the Layer 2 connection
206 ARGUS The selected B-channel is already busy.
210 A ARGUS No response to the clear-down ( REL sent, no REL_CMP/
REL_ACK received from network)
220 A ARGUS Remote end signaled that it is in State 0.
245 E ARGUS Keypad sent via ESC, but no response was received from
network
250 E ARGUS FACility was sent, but no response was received from network