Operation Manual

ARGUS
A
RGUS 125 47
Parallel call display while recording
The ARGUS searches all of the D-channel signals sent for a SETUP. If a SETUP is
detected, the <TALK> softkey will be displayed.
On a PRI , the ARGUS saves a timestamped report of any changes in the following alarms/
states:
- Signal
- FAS
- CRC4det
- A bit
- AIS
The ARGUS will check the following values and counters every second and, in the event of
a change, will save them:
- Sa5-Bit (Rx) / (Tx)
- Sa6-Bit (Rx) / (TX)
- E-bit
- Ecnt
- CRC Err.
- CRC rel.
- Cod.Err.
- Cod.rel
- Frm.Err.
For information on passively listening-in when the ARGUS is not recording, see page 43.
<TALK> Display the call parameters of the last SETUP received (see page 42).