Interpreting the test results:
If the outgoing call is not successful, it is not possible to make a statement about an
incoming call. Therefore, you will never see “- +” or “- *” on the display.
For outgoing, the Fax G3 service is OK. No statement
is possible about incoming.
The error code 63 gives the coded cause of the error
(see the table in the Appendix).
In this case, it is recommended that you have
someone place a call to the access under test using
this service.
The services Fax G4 and Mixed Mode are supported
for outgoing calls.
The Teletex service is supported in both directions.
If an error of error class A occurs (see “Supplementary Services Tests – Error messages”
on page 70.) the Service test will be aborted. An error of any other error class will coded in
decimal (in the example above 63), assigned to the respective service and then displayed.
Display Explanation
+ + The self call functions OK or the remote end can take the call for
this service
+ - The call was sent successfully, however, it was rejected at the
remote end due to a lack of authorization.
(Error class D in a B-channel message e.g. in a SETUP_ACK or
CALL_SENT)
- An outgoing call with this service is not possible
(Error class D without a B-channel message)
+ * The call was sent successfully, the call back or call to the remote
end failed (e.g., remote end busy or no B-channel available for the
call back).
* Wrong number, no B-channel available or other error
(Error class B, C or E without a B-channel message)
An example: