Datasheet

6 Operation on an ADSL Access
34 ARGUS 141
Settings: Explanation:
Access parameters
Phys. parameters
ADSL: Access parameters for the ADSL connection
ADSL mode
Different ADSL modes can be selected depending on the national
variant of the ARGUS. The selected ADSL mode must be compatible
to ATU-C (network-side). If the ADSL mode “Annex A Auto” is
selected, the ARGUS will automatically determine the configuration of
the DSLAM (G.DMT or ANSI) and set itself accordingly.
Default setting: depends on country
Rated Values
Use the keypad to enter the upstream and downstream comparison
values for the ATM bitrate [kbit/s]. If the current bitrates on the ADSL
connection exceed the rated values, the ARGUS will display "OK“,
otherwise it will display "FAIL“.
Default setting: d: 0 and u: 0
Shutdown mode The type of disconnect used for the ADSL connection.
Dying Gasp only (ADSL2+) or Orderly Shutdown.
Default setting: Dying gasp
Protocol: Selection of the transfer protocol that the ARGUS should use for the
test (e.g. for an IP test).
Protocols for ADSL:
PPPoE (PPPoEoA) - Point-to-Point Protocoll over Ethernet
PPPoA - Point-to-Point-Protokoll over ATM
EoA (IPoE, IPoEoA) - Ethernet over ATM
IPoA - Internet Protokoll over ATM
Default setting: PPPoE
ATM: Settings for Asynchronous Transfer Mode
Standard VC The identifier of the virtual channel in the ATM cells -
Virtual Path (Channel) Identifier
VPI / VCI VPI:
VCI:
Enter Virtual Path Identifier
Enter Virtual Channel Identifier
Ranges: VPI: 0 to 127, VCI: 32 to 255
Default: depends on country