Owner's manual

0040506001 1811 Page 15
Operating and installation instructions
Electric thrust actuator ARI-PACO 1,6 kN
5.5.2 Additional switching module in the ARI-PACO 1,6 D
Additional switching module in the actuating drive ARI-PACO 1,6 D for feedback of the two
valve positions.
Both limit switches (torque switch), DE3 and DE4 switch parallel to the torque switches DE1
and DE2.
5.5.2.1 Insertion and connection of the limit switch
Fig. 8
ATTENTION !
- Carry out insertion only on a linear actuator switched to a voltage-free state!
(mains voltage switched off and secured against being accidentally switched
on) .
Parts
4 pcs. Securing rings
1 pcs. Terminal strip shield
2 pcs. Cable ties
2 pcs. Self-tapping screws
1 pcs. Module limit switch ( pre-assembled ) consisting of: 2 switch
1 cable set
1 clamping strip
Contact switches in
the upper end position
from 41-42 to 41-44
Contact switches in
the lower end position
from 61-62 to 61-64