Manual
Table Of Contents
- Contents
- 1.0 General information on operating instructions
- 2.0 Notes on possible dangers
- 3.0 Storage and transport
- 4.0 Description
- 5.0 Installation
- 6.0 Putting the valve into operation
- 7.0 Care and maintenance
- 8.0 Troubleshooting
- 9.0 Troubleshooting table
- 10.0 Dismantling the valve or the body
- 11.0 Warranty / Guarantee
- 12.0 EC declaration of conformity

Page 12 Rev. 0040805000 4608
Operating and installation instructions
CONA
®
S - Ball float steam traps
7.2 Changing the installation position
(refer to Fig. 1 page 4- Fig. 5 page 6 und Fig. 7 page 12)
- Position body (Pos. 1) as desired, bearing in mind the direction of flow.
- Remove hood (Pos 16), then slacken hollow-core screw (Pos. 24.10) approximately 1/2
turn.
- Rotate controller (Pos. 24) 90º in the direction required
- Tighten hollow-core screw (Pos. 24.10) by holding against nozzle part (Pos. 24.11).
- Inspect and if necessary replace body seal (Pos. 17).
- Put on hood (Pos. 16) with the drain plug (Pos. 50) pointing diagonally down.
- Fit hexagonal nuts (Pos. 28) (see 7.5) and tighten crosswise.
PN63:
- A resilient sleeve (Pos. 30) is also fitted to the union of body (Pos. 1) and hood (Pos 16).
ATTENTION !
The vent tube (Pos. 24.12) must point upwards!
Fig. 7: Controller, cpl.