DRAINING FUEL SYSTEM
1. Move unit to an open, well-ventilated area with no
flames or sparks.
2. Remove fuel tank cap and siphon fuel into a clean
gasoline container.
3. Reinstall fuel tank cap and tighten.
4. Start engine to burn remaining fuel in fuel system and
leave engine running until it “runs dry” and stops.
Refer to Operator’s Manual for engine start procedure.
5. Stop engine, remove key and close fuel valve.
SERVICE POSITION
See Figure 2.
NOTICE: NEVER store unit in service position.
SEPARATE HOUSING FROM FRAME
Remove Auger Housing
IMPORTANT: Save all hardware for reinstallation.
1. Stop engine, remove key and wait for moving parts to
stop and for hot parts to cool.
2. Disconnect spark plug wire from engine.
3. Remove hardware retaining chute gear cover to chute
pedestal and remove cover.
IMPORTANT: For Models 921045, 921046, 921047,
921048, 921049, 921323, 921324, 921325, advance to
step 7.
Model 921326
See Figure 3.
1. Remove hairpin from hex rod and remove hex rod
from chute gears.
WARNING: AVOID INJURY. Before placing unit
in service position, drain fuel from tank and fuel
system. See Draining Fuel System on page 7.
Make sure unit is secure and will not tip.
Figure 2