Freeze Protection and Smart Winter Cycle
InanAriesContinuousCirculatingSpa,thepotentialforfreezedamageis
almostnonexistent,asmovingwaterdoesn’tquicklyfreeze,andthewater
iskeptheatedtoaminimumtemperature.WiththeadditionoftheAuto-
Purgefunction,freezedamageisveryrare.
Inaddition,thesystemmonitorsthetemperaturearoundthespaequip-
ment.Whenseverecoldisdetected,theSmartWinterCycletakeseffect.
Allpumpswillcomeonandrunfor1minute.Theywillcontinuetocycle
onagain,thestarttimevaryingfrom2-hourto15-minuteintervals,de-
pendingontheseverityofthetemperaturearoundtheequipment.
Warning! Aries recommends never draining a spa or leaving a spa
drained at any time of the year, especially for the winter. Regardless of
draining procedures used, there will always be a small amount of water
remaining in the plumbing lines or equipment. In wintertime, this water
can freeze and expand, causing serious damage. Aries Spas does not war-
ranty freeze-damage done to spas left drained.
Internal High Limit (Overheat) Switch
Yourspaequipmentpackisequippedwithaheateroverheatsensor.This
sensorprotectsyourheaterbyturningitoffincaseswherethewatertem-
peratureintheheaterhasreachedahigher-than-normalcondition.This
canhappenwhenyourlteriscloggedordirtyenoughtoslowthewater
owandwateristrappedintheheaterforlonger-than-normalperiodsof
time.
IftheLimitSwitchtrips,thedigitaltemperaturereadoutwillash,in-
termittentlyreading“OH”.This“IntermediateOvertemp”willdisable
theheateruntilthespawaterinsidetheequipmentcoolsdown.Whenthe
displaystopsashing,theheatersfunctionisrestored.
The“CatastrophicOvertemp”happenswhentemperatureshavereacheda
criticaldegree.Whenthishappens,thedisplaywillread“HL”.Youmust