Owner`s manual

Page 22
Aries Spas • User Manual
Troubleshooting Guide
Problem Possible Causes/Solutions
Spa Equipment does not operate. Nothing works.
GFCI has possibly tripped.
ResetGFCIonspapackbypushing“reset”.IfGFCIresetsforamo-
ment,thentripsagain,see“Blowerdoesnotwork”below.
Household circuit breaker has tripped.
Switchbreakerto"Off"position,thenresetto"On".
Equipment is not wired correctly.
Refertowiringdirectionsinyourequipmentmanual.Ifyouhaveques-
tions,callyourspadealerorequipmentmanufacturer.
Can hear Circulating Pump running, but water is not circulating.
Knife valve(s) closed.
Shutoffspaimmediately.Otherwise,yourequipmentwill“dry-re”
and burn out.Makesureallknifevalvesareinopenposition(pulled
up).
Circulating Pump has drawn air and lost prime.
Makesurethatthewaterlevelinthespaisapproximatelytothetopslit
of the Skimmer.TurnThermostatto“off”toprotectheater. To release
airfromthesystem,withpumprunning,openBleed Valve located on
theFilterlid.(ThisisasmallscrewlikettingontopofthePressure
Filter.)WaituntilwaterstartstospurtfromtheBleedValve,thenre-
close.
Letpumprunforabouttenminutes.Ifprimehasnotbeenrestored,
momentarilyloosenthequick-releasenutontherightsideoftheheater
toreleaseairthathasbeentrappedinthepipes,thenretighten.
Don’t let the pump run for more than ten minutes without prime. To do
socouldcauseseriousdamagetoyourequipment.If,after10minutes,
yourpumphasnotpickedupprime,wait1hourandtryagaintorestore