Owner`s manual

Page 24
Aries Spas • User Manual
(orovernight)forthewatertocoolsufcientlytoallowresetting.
(Clogged,dirtyFilterCartridgecancause“LimitReset”Buttontotrip.)
Spa water is too warm and won't cool off
You've heated the water too warm, and the outside
temperature is hot, not letting the water cool .
TurndowntheThermostat,andaddcoolwatertoyourspa.Iftheout-
sidetemperatureisveryhot,youmighttryaddingsomeice,also.This
willhelpspeedtheprocessofcoolingthewater.
Jet Pump does not work
Air hose that activates “Jets” Button has come loose,
either at back of “Jet” Button or at back of Equipment
Pack.
Makesurethatairhoseisattachedrmlytobackof“Jet”buttonand
tothettingontheEquipmentPack.Inspectthehoseforvisibleleaks
ordamage.Ifanyarefound,replacetheairhose.Examinethehosefor
obstructions,suchasinsects(reantsareacommonculprit).Clearany
obstruction found.
There is an air lock inside the Jet Pump system (this is a
common problem in in-deck installations, especially after
spa has been drained and relled).
Afterturningsystemoff,locatetheQuickCouplerclosesttothepump
thatisnotoperating.Loosenitbyturningcounterclockwiseuntilwater
startsowingout.Retightenandtrytooperatethesystemagain.
Can hear Jet Pump running, but water is not circulating
All jets are partially or fully closed.
Shutoffspaimmediately,otherwiseyourjetpumpmayoverheatand
possiblyburnout.Makesuretoopen3jetsatleast75%.
Knife Valves are partially or fully closed.
Shutoffspaimmediately,otherwiseyourJetPumpmayoverheatand
possiblyburnout.MakesuretoopenallKnifeValvescompletely.
Nothing works except Air Blower Pump, and it only pumps at very