Aries Spas • User Manual
slow speed
“Pump/Blower” Fuse (on front of Equipment Pack) has
blown out.
Replacethefuse(availableathardwareandautopartsstores)andtryto
restartJetPumpandAirBlowerPump.
Nothing works except Air Blower Pump and Light
The system has been incorrectly wired and is only
receiving 110 power, intead of 220.
Callyourelectrician,orcallAriesServiceDepartmentforproperwir-
inginstructions.
Air Blower does not work
Air Blower Pump has overheated and tripped its internal
Thermal Overload switch.
TheThermalOverloadwillresetitselfaftertheAirBlowerPumphas
sufcientlycooleddown.
Air hose that activates “Blower” button has come loose,
either at back of “Blower” button or at Equipment Pack.
Makesurethatairhoseisattachedrmlytobackofthe“Blower”
buttonandtothettingontheEquipmentPack.Inspectthehosefor
visibleleaksordamage.Ifanyarefound,replacetheairhose.Exam-
inethehoseforobstructions,suchasinsects(reantsareacommon
culprit).Clearanyobstructionfound.
When Air Blower is turned on, all equipment shuts off and won't
restart
Air Blower has gotten wet.
The GFCIbreakerhastrippedbecauseofmoisture.Themostcommon
causesare:
1)overllingofthespa(orlargebatherload)causingwatertooverow
the P-trap.
2)Largeamountsofhumidityorrain,runofffromsprinklers,etc.
To correct the problem, drain spa water to appropriate level, if neces-
sary.Makesurethereisnostandingwaterunderequipment.Reset