Owner`s manual
Page 26
Aries Spas • User Manual
GFCI.IfGFCIimmediatelytrips,theblowermaystillhavemoisturein
it.Itmaytakeuptoafewdaysfortheblowertodrysufcientlytobe
abletoresettheGFCI.If,afterafewdays,theproblempersists,contact
yourspadealerorAriesServiceDepartment..
Can hear Air Blower motor, but there are no bubbles in the spa
The pipe may have become disconnected from the blower.
LocatetheAirBlower,andchecktoseeifthepipehasbecomediscon-
nected.Ifso,pushthepipebackintotheopeningintheblower.(This
pipewasintentionallyleftunglued.)
Light won't turn on
The air line between the light connection on the equipment
pack and the “Light” button has become clogged, or has
come loose from the light button or the equipment.
Checkandrepairtheairlineinthesamemannerasdescribedin“Can
hearpumprunning,butwaterisnotcirculating”above.
The light bulb is burned out.
Inportablespas,takeoffthebackofthelightandchangethebulb.
Replacementbulbscanbefoundatmostlargeautomotivepartsstores,
oratAries.Someingroundspasareequippedwithswimmingpool-
typelights,accessiblefromthefront.Contactyourspadealerforbulb
replacement instructions.
Water in spa is “ugly” or smells bad
Water used to ll the spa was dirty, or water in the piping
or air channel of the spa was dirty.
Itcantakeyourspaadayortwotoclearupwheninitiallylled.Run
CirculatingPumpcontinually.Inextremecases,especiallywhenaspa
hasbeenlledwithwellwater,itmaybenecessarytodrainandrell
thespa,usinglteredwater.
Water in the air tubes has become stagnant, due to lack of
circulation.
MakeahabitofturningontheAirBlowerPumpforatleast30sec-
ondseachtimeyouusethespa.Thiswillushtheairtubesofstanding