G.F.C.I. Breaker Reset Button
Your spa equipment pack is equipped with a G.F.C.I. breaker.
This breaker protects against accidental electrical shock caused by
water or excessive moisture on the electrical components.
To make sure that the G.F.C.I. breaker is operating properly, press
the black button labeled “Test”. If operating normally, the spa equip-
ment pack will shut off, and will require resetting. If water comes into
contact with the components, the black button will pop out. To reset,
push the red “reset” button. If the black button immediately pops out
again, wait a sufcient amount of time for the moisture to evaporate,
and try to reset again. If the black button continues to pop out, call
your spa dealer or the factory.
Overheat Protection Button
Your spa equipment pack is equipped with a heater overheat
sensor. This sensor protects your heater by turning off power to the
heater in cases where the water temperature in the heater have reached
a higher-than-normal condition. This can happen when your lter is
clogged or dirty enough to slow the water ow and trap water in the
heater for longer-than-normal periods of time.
If the Overheat Button pops out, thoroughly clean your lter to
restore maximum water ow before attempting to reset it, .
To reset, push the button inward. If it will not reset, wait until the
water inside the heater has had sufcient time to cool, then try again
to reset. (Depending on the outside temperature, this could take up to
several hours.)
Heater Indicator Light
This light illuminates any time the heater is operating.
Spa-side Controls
Single Function Controls
The following function buttons operate by pushing once to turn
on, and pushing again to turn off.
“Jets” Button
This button operates the water jets (ttings in the spa wall that
circulate the water into the spa under pressure). On systems with one
circulating pump and two high-speed pumps, several of the jets will be
powered by the “Auxiliary/Light” button (below).