“off” position or the lowest setting possible.
Set the two Rocker Switches to the desired settings (refer to
“Rocker Switch Settings” in the “Operation” section). We recommend
a combination of the IMS Switch to “Continuous”, and the Heating
Switch to “Temperature Demand”.
Turn on the main power switch. The IMS motor should start run-
ning immediately. If it does not, recheck your Rocker Switch settings
and try again.
Once the IMS motor is running and water is circulating properly,
you should be able to observe water and/or bubbles coming from the
Ozone and the Ozone Recovery jets, usually located near your steps
and/or the light. This indicates that the water is circulating properly.
If no water ow is observed, do the following:
1. Listen to make sure that the IMS pump motor is running.
2. Make sure that the knife ("T" shaped) valves are open. These
valves are located on the pipes on either side of the equipment
pack. They are opened if the handles are extended as far out as
they will go.
“Heater System Control”
DrainG.F.C.I. BreakerThermostat Heater LightPump
Fuse IMS Rocker SwitchTimeClock Overheat Button Knife
Valve
Heater Rocker Main Power
Switch Switch Heater