Installation Guide

4
Dimensions and Clearances
F
M
D
C
B
A
E
H
G
I
Recirculating
Kit height
J
Duct cover
Kit height
K (6”)
L (12”)
ALZ430SSA ALZ436SSA
A 30” (76 cm) 36” (91.54 cm)
B 23
7
64 (58.7 cm)
C 17
63
64 (45.7 cm)
D 12
3
64 (30.6 cm)
E 2
10
32(5.9 cm)
F 29
4
32” (74 cm) 35
7
32”(89.5 cm)
G 7
3
32 (18 cm)
H 2
9
16” (6.5 cm)
I
13
32” (1 cm)
J 21
59
64 (55.7 cm)
K 23
15
16 (60.8 cm)
L 29
59
64 (76 cm)
M 6" (15.24 cm)
Electrical Requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
To contact a qualied electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
— latest edition*, or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and
all local codes and ordinances.
If codes permit and a separate ground wire is used, it is recom-
mended that a qualied electrician determine that the ground
path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is
required.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools designed
and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with local
codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specied on the model/serial rating plate.
The model/serial plate is located behind the lter on the rear
wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition and all local codes and
ordinances.