Installation manual

AV-Series System Programming Manual
0-14
INITIALIZATION
129 CO Delay Time
<-- Program Status Area
<-- SSS=000~255
Def.=003=3x40=120 ms
Description:
When accessing a free CO line the system will delay the setting time
duration to open the internal CO loop. All digits dialed during the setting
delay time interval will be received by the system and will not be sent out
until the setting time is reached.
130 CO Access Delay Time
<-- Program Status Area
<-- SSS=000~255
Def.=000=0 sec.
Description:
A free CO line can not be retrieved after it is released until the setting time is
reached.
131 Door Ringing Delay Time
<-- Program Status Area
<-- SSS=000~255
Def.=000=0 sec.
Description:
When the Door Sensor is activated the assigned stations in PROGRAM
ZONE 602 will not be ringing until the setting time is reached.
Interrelation Zones: Programs Zone 127, 221 and 233
129 Swon Delay
Time=003 (
40ms)
Aristel
TM
AV
SERIES
130 Co Delay tm
Time=000 Sec
Aristel
TM
AV
SERIES
131 Door SensorD
Time=000 Sec
Aristel
TM
AV
SERIES
NOTE 5: Busy Tone (II) is only recognized if the following
parameters are effective.
1. Busy Tone On (II) ----- Program Zone 127.
2. Busy Tone Off (II)
-----
Program Zone 127.
Interrelation Zone: Program Zone 216
Interrelation Zones: None
Interrelation Zone: Program Zone 602