Installation manual

AV-Series System Programming Manual
0-88
INITIALIZATION
605 CO Lock
<-- Program Status Area
<-- IP=CO Number
Refer to NOTE 32,
Point 1.
S=0 ~ 3
Def.= [ 0 0 0 0 0 0 0 0 ]
Description:
There are four (4) different conditions which can be selected for CO
line Lock function.
S = 0 = Unlock both incoming and outgoing
S = 1 = Lock outgoing, unlock incoming.
S = 2 = Lock both outgoing and incoming and turn CO LED OFF.
S = 3 = Lock both outgoing and incoming and turn CO LED ON.
606 CO Incoming Ringing Frequency
Assignment
<-- Program Status Area
<-- IP=CO Number
Refer to NOTE 32,
Point 1.
S=0 ~ 9
Def.= [ 0 0 0 0 0 0 0 0 ]
Description:
Enables the user to recognize the different incoming ringing
frequencies. Nine (9) different ringing frequencies can be selected for
each CO line.
S = 0 = According to the Station Ringing Frequency
S = 1 = The 1
st
ringing frequency level; 447.5Hz±419.5Hz
S = 2 = The 2
nd
ringing frequency level; 516.4Hz±447.5Hz
S = 3 = The 3
rd
ringing frequency level; 559.4Hz±479.5Hz
S = 4 = The 4
th
ringing frequency level; 610.2Hz±479.5Hz
S = 5 = The 5
th
ringing frequency level; 671.3Hz±479.5Hz
S = 6 = The 6
th
ringing frequency level; 745.9Hz±516.4Hz
S = 7 = The 7
th
ringing frequency level; 839.0Hz±610.2Hz
S = 8 = The 8
th
ringing frequency level; 959.0Hz±671.3Hz
S = 9 = The 9
th
ringing frequency level; 1118.8Hz±839.0Hz
605 CO Lock IP
0 0 0 0 0 0 0 0
Aristel
TM
AV
Interrelation Zones: None
606 CO Fre. IP
0 0 0 0 0 0 0 0
Aristel
TM
AV
NOTE 35: AV-8/AV-12 ---> CO Loud Bell = 01
NAV-8 ---> CO Loud Bell = 01 ~ 02
AV-38 ---> CO Loud Bell = 01 ~ 02
AV-64 ---> CO Loud Bell = 01 ~ 04
AV-256 ---> CO Loud Bell = 01 ~ 09