Technical information

58
FIG. 7.25
FIG. 7.26
FIG. 7.27
FIG. 7.28
7.3.6. RE
MOVING THE
CO
NDENSATE
TR
AP
(T
UBE
)
1. Open the clamp “Q” and remove the condensate trap
c
onnection pipe (F
IG.
7.25);
2. Unscrew the screw “R” (FIG. 7.26);
3. Remove the condensate tube.
7.3.7. RE
MOVING THE
CO
NDENSATE
TR
AP
1. Remove the condensate trap tube (see section 7.3.6);
2
.
U
nscrew the screw “S” (F
IG.
7.27);
3. Remove the blanking cap “T” (FIG. 7.28);
4. Remove the trap from the boiler.
N
OTE:
T
ake care when removing the blanking cap to
p
lace a container under the boiler as this will
release the contents of the condensate trap.
Q
R
S
T