Installation and Use

46
GB
MONOSPLIT INSTALLATION
1L
2N
S
W
L
N
3. Fasten the cables using the cable clamp.
4. Put the cover back in place, ensuring it is positioned correctly.
3.3 Connecting to the mains electricity supply
Appliance connection must adhere to European and national standards, and must be protected by a 30 mA differen-
tial switch. Connection to the mains must be permanent (not using a plug) and equipped with an omnipolar switch
complying with current CEIEN standards (contact air gap of at least 3 mm when open, preferably fi tted with a fuse).
Proper connection to an effi cient earthing system is essential for ensuring safe operation of the device.
1. Remove the cover.
2. Connect the conductors to the screw terminals. Screw the terminal board screws tightly to avoid any loosening.
3. Fasten the cables using the cable clamp.
4. Put the cover back in place, ensuring it is positioned correctly.
MONOSPLIT INSTALLATION
1L
2N
S
W
L
N
3.4 Connection types
MONOSPLIT INSTALLATION
External unit
model
Power supply Switch type Connection cable
Connection
cable type
Power supply
cable
Power supply
cable type
ALYS 25 MC8-O 220-240 ~ 50 Hz 10 A 5G 1,5 mm
2
H07RN-F
3G 1,5 mm
2
H07RN-F
ALYS 35 MC8-O 220-240 ~ 50 Hz 16 A 5G 1,5 mm
2
H07RN-F
3G 1,5 mm
2
H07RN-F
ALYS 50 MC8-O 220-240 ~ 50 Hz 16 A 5G 1,5 mm
2
H07RN-F
3G 1,5 mm
2
H07RN-F
Power supply