Installation Instructions

13
EN
Part 5 - Installation Checklist
Water Heater Location Yes No
Close to area of heated water demand
Indoors and protected from freezing temperatures
Area free of  ammable vapors
Provisions made to protect area from water damage
Su cient room to service heater
Relief Valve Ye s N o
Temperature and Pressure Relief Valve properly installed and discharge line run to open drain
Discharge line protected from freezing
Wiring Ye s N o
Power supply voltage agrees with water heater rating plate
Branch circuit wire and fusing or circuit breaker of proper size
Electrical connections tight and unit properly grounded
Water Supply Ye s N o
Water heater completely  lled with water BEFORE operating the unit
Air purged from water heater and piping
Water connections tight and free of leaks
Table 3 - Installation Checklist
Part 6 - Operation
Tank must be full of water before the power is turned on. The heating element will be damaged if energized for
even a short time while tank is dry. Failures due to dry- ring ARE NOT covered by warranty.
A. Starting and Testing
For models not  tted with a switch:
Supply power to the water heater by plugging in the power cord (2.5 and 4 Models) or turning on the circuit
breaker (8 Model).
If the light does not turn on, turn the control knob in a clockwise direction.
The light will turn on until the water temperature has reached the thermostat temperature setting. The light
will come back on any time the water temperature inside the tank drops below the thermostat setting.
B. Thermostat Adjustment
The temperature of the hot water is adjusted by rotating the knob (M, see Figure 5) located on the front cover.
Turn the knob clockwise to increase temperature.
Turn the knob counterclockwise to decrease temperature.
Do not attempt to repair this water heater yourself. Call a quali ed service technician for assistance. Always
turn o the power supply to the heater prior to servicing or draining the heater. Failure to do so could result in
property damage, severe personal injury, or death.
Part 7 - Maintenance
For most of these maintenance operations, the water will have to be drained from the heater. For all of these
operations, the power cord should be disconnected (2.5 or 4 Models) or the power turned o at the circuit
breaker (8 Model), and the front cover removed.