Specifications

Merloni Elettrodomestici
FULL NO FROST COMBINED UNIT (2003)
Technical Manual
GB 04-10-28/01 20-43
Language Issue/Edition Page
7. Probes
These are temperature sensors able to associate measurements in degrees centigrade
with resistive values that are easily read and managed by the microprocessor on the
board.
•The Refrigerator Air Sensor, located inside the compartment, allows the
temperature set by the user to be adjusted. It is managed by the electronic board and
the user controls its adjustment. The appliance continues to function in the event of
a thermostat malfunction or short-circuit thanks to a timed thermostat run mode
managed by the electronic board. The sensor cannot be replaced. The “Autotest”
function will confirm a malfunction.
The Freezer Air Sensor, located inside the compartment allows the temperature to
be adjusted, signalling critical temperature thresholds to the board. It is managed by
the electronic board and the user controls its adjustment. In the event of a freezer
probe malfunction or short-circuit, freezer compartment alarms will not
be signalled to the electronic board. The freezer will continue to ensure efficient
freezing thanks to a timer run thermostat. Also this sensor cannot be replaced.
The “Autotest” function will confirm the malfunction.