Product Sheet

10
MODEL
GENUS ONE HYBRID
. . ./4 LINK . . ./5 LINK . . ./7 LINK .../9 LINK .../11 LINK
13 Air to water heat pump YES
14 With supplementary heater YES
15 Rated heat output [kW] 4 5 7 9 11
16 Annual energy consumption [kWh] 2939 3635 4700 5876 7069
17 Seasonal space heating energy efficiency [%] 127 130 128 129 132
18 Sound power level, outdoor [dB] 57 59 61 63 63
19 Sound power level, indoor [dB] * * * 15 15
20 Declared capacity and coefficient of performance for heating at indoor conditions 20°C and outdoor temperature
Tj, LWT 55°C
21 Climate AVERAGE
ηs 127 130 128 129 132
Prated [kW] 4,64 5,86 7,45 9,39 11,55
SCOP 3,26 3,33 3,27 3,30 3,38
22 Bivalent temperature [°C] -7
23 Operating limit temperature [°C] -20
24 Heating water operation limit temperature [°C] 60
25 Capacity Tj = -7 °C [kW] 4,10 5,19 6,59 8,31 10,22
COPd Tj = -7 °C 2,29 2,26 2,17 2,32 2,31
Capacity Tj = 2 °C [kW] 2,50 3,17 4,18 5,33 6,24
COPd Tj = 2 °C 3,27 3,32 3,30 3,33 3,43
Capacity Tj = 7 °C [kW] 1,62 2,14 2,58 3,48 4,00
COPd Tj = 7 °C 3,69 3,90 3,87 3,80 3,80
Capacity Tj = 12 °C [kW] 1,51 1,50 2,54 4,03 4,07
COPd Tj = 12 °C 5,29 5,41 5,40 5,81 5,63
Capacity Tj = biv [kW] 4,10 5,19 6,59 8,31 10,22
COPd Tj = biv 2,29 2,26 2,17 2,32 2,31
Capacity Tj = -10 °C [kW] 3,92 5,00 7,06 9,44 11,54
COPd Tj = -10 °C 2,13 2,14 1,95 1,70 2,06
26 Capacity Tj = Operating limit temperature [kW] 2,46 3,18 4,90 2,06 4,29
27 COPd Tj = Operating limit temperature 1,52 1,54 1,51 0,54 0,92
21 Climate COLDER
ηs 128 129 128 109 113
Prated [kW] 7,37 8,58 11,06 13,91 17,24
SCOP 3,28 3,30 3,28 2,81 2,91
22 Bivalent temperature [°C] -7
23 Operating limit temperature [°C] -20
24 Heating water operation limit temperature [°C] 60
25 Capacity Tj = -7 °C [kW] 4,46 5,19 6,70 8,42 10,44
COPd Tj = -7 °C 2,74 2,71 2,62 2,77 2,73
Capacity Tj = 2 °C [kW] 2,89 3,17 4,13 5,12 6,35
COPd Tj = 2 °C 3,77 3,89 3,95 3,67 3,83
Capacity Tj = 7 °C [kW] 1,75 2,03 2,76 3,75 4,19
COPd Tj = 7 °C 5,33 4,95 5,13 5,12 5,06
Capacity Tj = 12 °C [kW] 1,61 1,60 2,68 4,30 4,28
COPd Tj = 12 °C 6,21 6,35 6,26 6,96 7,06
Capacity Tj = biv [kW] 4,46 5,19 6,70 8,42 10,44
COPd Tj = biv 2,74 2,71 2,62 2,77 2,73
26 Capacity Tj = Operating limit temperature [kW] 2,46 3,18 4,90 2,06 4,29
27 COPd Tj = Operating limit temperature 1,52 1,54 1,51 0,54 0,92
21 Climate WARMER
ηs 139 151 151 153 161
Prated [kW] 2,32 2,98 4,38 6,26 7,45
SCOP 3,54 3,84 3,84 3,91 4,10
22 Bivalent temperature [°C] 2
23 Operating limit temperature [°C] -20
(ErP)
TECNICAL DATA  DATI TECNICI
TECHNICKÁ DATA  MŰSZAKI ADATOK  TECHNICKÉ PARAMETRE TECHNICKÁ DATA