Product Sheet

11
24 Heating water operation limit temperature [°C] 60
25 Capacity Tj = 2°C [kW] 2,32 2,98 4,38 6,27 7,45
COPd Tj = 2 °C 2,18 2,33 2,24 2,33 2,38
Capacity Tj = 7 °C [kW] 1,53 1,92 2,81 4,18 5,05
COPd Tj = 7 °C 2,77 2,98 3,09 3,31 3,47
Capacity Tj = 12 °C [kW] 1,61 1,59 2,63 4,12 4,15
COPd Tj = 12 °C 5,66 5,69 5,50 5,73 5,86
20 Declared capacity and coefficient of performance for heating at indoor conditions 20°C and outdoor temperature
Tj, LWT 35°C
21 Climate AVERAGE
ηs 180 177 178 189 189
Prated [kW] 5,21 5,80 7,89 10,61 12,56
SCOP 4,58 4,49 4,54 4,80 4,80
22 Bivalent temperature [°C] -7
23 Operating limit temperature [°C] -20
24 Heating water operation limit temperature [°C] 60
25 Capacity Tj = -7 °C [kW] 4,61 5,13 6,98 9,38 11,11
COPd Tj = -7 °C 3,30 3,15 3,10 3,29 3,19
Capacity Tj = 2 °C [kW] 2,80 3,15 4,31 5,71 6,77
COPd Tj = 2 °C 4,48 4,42 4,59 4,67 4,61
Capacity Tj = 7 °C [kW] 1,82 2,01 2,76 3,67 4,35
COPd Tj = 7 °C 5,44 5,28 5,30 6,01 6,16
Capacity Tj = 12 °C [kW] 1,54 1,54 2,60 4,44 4,41
COPd Tj = 12 °C 7,21 7,28 6,87 8,76 8,45
Capacity Tj = biv [kW] 4,61 5,13 6,98 9,38 11,11
COPd Tj = biv 3,30 3,15 3,10 3,29 3,19
Capacity Tj = -10 °C [kW] 4,08 5,03 7,57 9,15 12,05
COPd Tj = -10 °C 2,99 2,82 2,78 2,77 2,8
26 Capacity Tj = Operating limit temperature [kW] 2,92 3,69 5,51 6,32 8,76
27 COPd Tj = Operating limit temperature 2,35 2,29 2,22 2,17 2,20
21 Climate COLDER
ηs 167 167 168 152 150
Prated [kW] 7,74 8,08 11,85 15,18 18,17
SCOP 4,26 4,24 4,27 3,88 3,82
22 Bivalent temperature [°C] -7
23 Operating limit temperature [°C] -20
24 Heating water operation limit temperature [°C] 60
25 Capacity Tj = -7 °C [kW] 4,69 4,89 7,17 9,19 11,00
COPd Tj = -7 °C 3,60 3,46 3,42 3,66 3,47
Capacity Tj = 2 °C [kW] 2,90 2,98 4,48 5,62 6,70
COPd Tj = 2 °C 5,06 5,11 5,36 5,10 5,00
Capacity Tj = 7 °C [kW] 1,83 1,95 2,90 3,72 4,39
COPd Tj = 7 °C 6,67 6,93 6,56 6,55 6,60
Capacity Tj = 12 °C [kW] 1,62 1,61 2,72 4,44 4,41
COPd Tj = 12 °C 7,80 7,88 7,43 8,76 8,45
Capacity Tj = biv [kW] 4,69 4,89 7,17 9,19 11,00
COPd Tj = biv 3,6 3,46 3,42 3,66 3,47
26 Capacity Tj = Operating limit temperature [kW] 2,92 3,69 5,51 6,32 8,76
27 COPd Tj = Operating limit temperature 2,35 2,29 2,22 2,17 2,20
21 Climate WARMER
ηs 225 232 223 240 245
Prated [kW] 2,80 3,47 4,85 6,65 7,96
SCOP 5,69 5,89 5,64 6,07 6,21
22 Bivalent temperature [°C] 2
23 Operating limit temperature [°C] -20
24 Heating water operation limit temperature [°C] 60
25 Capacity Tj = 2°C [kW] 2,80 3,47 4,85 6,65 7,96
COPd Tj = 2 °C 3,92 3,88 3,96 3,90 4,07
Capacity Tj = 7 °C [kW] 1,80 2,23 3,12 4,46 5,36
COPd Tj = 7 °C 5,05 5,15 4,99 5,44 5,51