Genus ONE Net Installation Manual

/ 25
INSTALLATION
Room Thermostat / Remote Clock Connection
To connect a room thermostat, it is necessary to:
1. Open the control panel
2. Loosen the cable clamp using a screwdriver and insert the
wires leading from the room thermostat
3. Connect the wires to the terminals as indicated in the gure
below, removing the link
4. If a remote time clock is to be tted, using a volt free switching
time clock connect the switching wires from the time clock
following points 1 - 3 above
5. If using an external time clock and room thermostat, these
must be connected in series as shown in diagram C,
6. Ensure that they are well connected and not subject to stress
when the control panel is closed
DO NOT CONNECT 240V TO ANY PERIPHERAL CONNECTIONS
Connector TA on PCB
(low voltage switching)
Connector TA on PCB
(low voltage switching)
Connector TA on PCB
(low voltage switching)
Cube Room sensor (wireless) Connection
To connect a room thermostat, read the instructions present in
the kit delivered with the gas boiler.
DO NOT CONNECT 240V TO ANY PERIPHERAL CONNECTIONS