Heating Brochure 2021

FLUE CONFIGURATIONS
FLUE TERMINAL POSITIONS
The need for alteration to flue components is almost completely
eliminated, making installation of the boiler quick and easy.
It is possible to site flue terminals in a variety of positions in
accordance with BS5440-1:2008.
Directly above/below an opening, air brick, opening windows, etc
Horizontally to an opening, air brick, opening windows, etc
Below gutters, soil pipes or drain pipes
Below eaves
From vertical drain or soil pipe
From an internal or external corner
Above ground roof or balcony level
From a surface facing the terminal
From a terminal facing the terminal
Vertically from a terminal on the same wall
Horizontally from a terminal in the same wall
Fixed by use of terminal and matched flashing plate
300
300
75
200
75
300
300
600
1200
1500
300
-
A:
B:
C:
D:
E:
F:
G:
H:
I:
J:
K:
L:
TERMINAL POSITION
MAX FLUE LENGTHS
OUR REFERENCE
Horizontal Coaxial 60/100 (mm)
Vertical Coaxial 60/100 (mm)
Horizontal Coaxial 80/125 (mm)
Vertical Coaxial 80/125 (mm)
Twin Pipe (equal lengths*)
18
8
8
32
32
36/36
30
7
7
24
24
26/26
24
8
8
33
33
24/24
35 38
6 6
6 6
24 27
24 27
23/23 16/16
MM
Coaxial Systems 60/100
Horizontal installation with no plume kit.
Product code:
3318073
Horizontal Coaxial Kit
Coaxial Systems 60/100
Horizontal installation with coaxial piping
and a plume kit.
Product code:
3318329
Plume Kit
(inc. 1000mm Horizontal Terminal)
Coaxial Systems 60/100
Vertical installation with coaxial piping
on a pitched roof.
Product code:
3318079
Vertical Starter
3318080
Vertical Flue
3318077
Coaxial Extension - 1000mm
3318009
Black Flexible Flashing Base Cap 12 – 40º
3318010
Red Flexible Flashing Base Cap 12 – 40º
TYPE 1
TYPE 2
TYPE 3
Ariston have an extensive array of flues and accessories which
can be applied to suit most flueing installation methods.
Ariston boilers are designed to be completely adaptable, whether you need
to alter flue components or wish to add accessories for comprehensive
temperature management or energy conservation.
FLUES AND ACCESSORIES
INSTALLING YOUR
ARISTON BOILER
FLUE TURRETS
ALTEAS ONE NET, GENUS ONE NET, CLAS ONE,
CLAS SYSTEM ONE, E-COMBI ONE AND E-SYSTEM ONE
32