Specification

Ariston GL2.5; GL4; GL6
+
Technical Specifications
With more than 25 years of experience selling tankless water heaters, Controlled Energy Corporation provides
unmatched knowledge and service to its customers. Sales, service, installation, and technical information are
just a toll-free call away. Or you can visit our web site.
Controlled Energy Corporation
340 Mad River Park, Waitsfield, VT 05673 USA
Toll-free: 866-642-3199 • Fax: 802-496-6924
email: sales@ControlledEnergy.com
website: www.ControlledEnergy.com
ARISTON GL2.5 GL4 GL6
+
Tank Volume 2.75 gallons 3.85 gallons 7.0 gallons
Dimensions 14” x 14” x 10
1
/
4” 14” x 14” x 12
1
/
4 17
1
/
2” x 17
1
/
2” x 14
1
/
2
Voltage 110/120v 110/120v 110/120v
Amperage 12.5 amps 12.5 amps 12.5 amps
Wire Size Plug-in Plug-in 12 gauge
Heating Capacity 1500 watts 1500 watts 1500 watts
Recovery at 90ºF Rise 7 gph 7 gph 7 gph
Temperature Range 65-145°F 65-145°F 65-145°F
Water Connections
1
/
2” NPT
1
/
2” NPT
3
/
4” NPT
Operating Pressure 150 PSI 150 PSI 150 PSI
Relief Valve Installed Installed Included
Ariston GL2.5 Installation
Simply tap into the cold water line and install the
heater directly at the sink. The 2.5- and 4-gallon
models plug into a standard 110-volt outlet. The
6
+
gallon model requires hard wiring. And when
you want to eliminate the wait for hot water but
need more volume, install the Ariston water
heater in-line with a larger hot water source.
In-line Installation
Independent Installation
Easy Installation
* gph = Gallons Per Hour