Technical information

38
commissioning
menu 2 - Boiler parameters
NOTE: To access the menus, see page 42
submenu 3 - parameter 1
Maximum Heating Power adjustment
submenu 2 - parameter 0
Soft light Ignition
submenu 3 - parameter 5
Heating ignition delay
Maximum Heating Power adjustment
The maximum heating power can be adjusted to
between the maximum power allowed by the boiler
and the minimum power.
The display shows the value between 100% (“99” on
the display) and 0% (“0”).
To check the maximum heating power, access
menu 2/sub menu 3/parameter 1, check the value
and, if necessary, modify it as indicated in the Gas
Regulation table. (below).
Checking slow ignition power
The soft light can be adjusted between the maximum
power (shown on the display as “99”, i.e. 100%) and
the minimum power (shown on the display as “1”, i.e.
1%).
To check the slow ignition power, access menu 2/sub
menu 2/parameter 0.
Heating ignition delay adjustment
This parameter menu 2/sub menu 3/parameter 5
- can be used to manually (0) or automatically (1) set
the delay time before the subsequent reignition of
the burner after it has switched o on reaching the
desired temperature in central heating mode.
By selecting manual (0), it is possible to set the delay
in minutes using the successive parameter (menu 2/
sub menu 3/parameter 6), to a time between 0 and
7 minutes.
Automatic selection means that the boiler will
establish the delay time based on the set-point
temperature.
gas setting
parameters
12 kW
18 kW
24 kW
G20
G31
G20
G31
G20
G31
lower Wobbe index
(15°C, 1013 mbar) (MJ/m3)
45,67
70,69
45,67
70,69
45,67
70,69
slow ignition
220
50
60
50
60
50
60
minimum fan speed(%)
233
00
00
02
02
05
05
maximum output fan speed (%)
234
70
70
80
80
85
85
gas valve restrictor(ø)
4,40
3,10
NO
3,80
NO
3,80
gas ow max/min (15°C, 1013 mbar)
(nat - m3/h) (GPL - kg/h)
max D.H.W
1,27
0,93
1,90
1,40
2,65
1,94
max C.H.
1,27
0,93
1,90
1,40
2,33
1,71
min
0,32
0,23
0,48
0,35
0,58
0,43
25
30
35
18
12
38
24