Technical information

45
settings - adjustment - problem identication menus
menu
sub-menu
parameter
description value
default etting
4 ZONE 1 PARAMETER
4 0 ZONE 1 TEMPERATURE SETTING
4 0 0 Zone 1 comfort temperature
setting "Comfort ambience T"
from 10 to 30 °C 19 Activated only with the modulating
device connected (option)
4 0 1 Zone 1 reduced temperature
setting "Reduced ambience T"
from 10 to 30 °C 16
4 0 2 Heating xed temperature
setting "Heating xed temp"
from 20 to 82 °C 70 Activated only with temperature
control and xed temperature
4 1 Entering access code 222 press the programming "+" button
to select 234 and press the meNu
button
4 2 ZONE 1 SETTING
4 2 0 Heating appliance
temperature value setting
0 = from 20 to 45°C (low temperature)
1 = from 35 to 85°C (high temperature)
1 select in the appliance type base
4 2 1 Basic heating control type
selection type depending
on the peripheral devices
connected
0 = xed ow temperature
1 = device On/O
2 = ambient sensor only
3 = external sensor only
4 = ambient sensor + external sensor
1 To activate heating control, press
the AUTO button. The Auto light is
illuminate
4 2 2 Slope 0_2 to 3_5 1_5
If the external sensor is
used, the boiler calculates
the most suitable heating
ow temperature taking the
external temperature and
the type of appliance into
account.
The type of curve must be
chosen according to the type
of appliance radiator and the
heat losses present in the
building.
temperatura di mandata all’impianto
bassa tempertaura alta tempertaura
temperatura esterna
valore di consegna
temperatura ambiente
°C
20
25
15
30
40
50
60
70
80
90
100°C
10
2.5 3.0 3.5 2.0
1.5
1.2
1.0
0.8
0.6
0.4
0.2
5 0 -5 -10 -15 -20 °C
4 2 3 Parallel shift - 20 to + 20 0
To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter the
calculated ow temperature and therefore the ambient temperature.
The shift value between - 20 and + 20 is shown on the display. Each level corresponds to a
1°C increase in the ow temperature
in relation to the initial setting.
4 2 4 Compensation 0 to + 20 20
if setting = 0, the temperature taken from the ambient sensor does not aect the calculation
of the setting. If setting = 20, the temperature taken has maximum inuence on the setting.
4 2 5 Zone 1 heating maximum
temperature setting
35 to + 82°C 82 if parameter 420 = 1
20 to + 45°C
45 if parameter 420 = 0
4 2 6 Zone 1 heating minimum
temperature setting
35 to + 82°C 35 if parameter 420 = 1
20 to + 45°C 20 if parameter 420 = 0
4 3 DIAGNOSTICS display only
4 3 0
Zone 1 room temperature
Activated only with the modulating
device connected (option)
4 3 1
Zone 1 set temperature
4 3 2
Zone 1 heat request
0=OFF
1=ON
4 3 3 NOT PRESENT
4 4 ZONE DEVICE MANAGEMENT
4 4 0 NOT PRESENT
External temperature
High temperature
Flow Temperature
low temperature
Ambient temperature
setting value