6
24 Heating water operation limit temperature [°C] 60
25 Capacité Tj = 2°C [kW] 2,32 2,98 4,38
COPd Tj = 2 °C 2,18 2,33 2,24
Capacité Tj = 7 °C [kW] 1,53 1,92 2,81
COPd Tj = 7 °C 2,77 2,98 3,09
Capacité Tj = 12 °C [kW] 1,61 1,59 2,63
COPd Tj = 12 °C 5,66 5,69 5,50
20 Declared Capacité and coecient of performance for heating at indoor conditions 20°C and outdoor temperature
Tj, LWT 35°C
21 Climate AVERAGE
ηs 180 177 178
Prated [kW] 5,21 5,80 7,89
SCOP 4,58 4,49 4,54
22 Bivalent temperature [°C] -7
23 Operating limit temperature [°C] -20
24 Heating water operation limit temperature [°C] 60
25 Capacité Tj = -7 °C [kW] 4,61 5,13 6,98
COPd Tj = -7 °C 3,30 3,15 3,10
Capacité Tj = 2 °C [kW] 2,80 3,15 4,31
COPd Tj = 2 °C 4,48 4,42 4,59
Capacité Tj = 7 °C [kW] 1,82 2,01 2,76
COPd Tj = 7 °C 5,44 5,28 5,30
Capacité Tj = 12 °C [kW] 1,54 1,54 2,60
COPd Tj = 12 °C 7,21 7,28 6,87
Capacité Tj = biv [kW] 4,61 5,13 6,98
COPd Tj = biv 3,30 3,15 3,10
Capacité Tj = -10 °C [kW] 4,08 5,03 7,57
COPd Tj = -10 °C 2,99 2,82 2,78
26 Capacité Tj = Operating limit temperature [kW] 2,92 3,69 5,51
27 COPd Tj = Operating limit temperature 2,35 2,29 2,22
21 Climate COLDER
ηs 167 167 168
Prated [kW] 7,74 8,08 11,85
SCOP 4,26 4,24 4,27
22 Bivalent temperature [°C] -7
23 Operating limit temperature [°C] -20
24 Heating water operation limit temperature [°C] 60
25 Capacité Tj = -7 °C [kW] 4,69 4,89 7,17
COPd Tj = -7 °C 3,60 3,46 3,42
Capacité Tj = 2 °C [kW] 2,90 2,98 4,48
COPd Tj = 2 °C 5,06 5,11 5,36
Capacité Tj = 7 °C [kW] 1,83 1,95 2,90
COPd Tj = 7 °C 6,67 6,93 6,56
Capacité Tj = 12 °C [kW] 1,62 1,61 2,72
COPd Tj = 12 °C 7,80 7,88 7,43
Capacité Tj = biv [kW] 4,69 4,89 7,17
COPd Tj = biv 3,6 3,46 3,42
26 Capacité Tj = Operating limit temperature [kW] 2,92 3,69 5,51
27 COPd Tj = Operating limit temperature 2,35 2,29 2,22
21 Climate WARMER
ηs 225 232 223
Prated [kW] 2,80 3,47 4,85
SCOP 5,69 5,89 5,64
22 Bivalent temperature [°C] 2
23 Operating limit temperature [°C] -20
24 Heating water operation limit temperature [°C] 60
25 Capacité Tj = 2°C [kW] 2,80 3,47 4,85
COPd Tj = 2 °C 3,92 3,88 3,96
Capacité Tj = 7 °C [kW] 1,80 2,23 3,12
COPd Tj = 7 °C 5,05 5,15 4,99