Installation and Maintenance

EN
15
LEGIONELLA BACTERIA FUNCTION
Legionella are small rod shaped bacteria which are a natural constituent of all fresh waters. Legionaries’ disease is a
pneumonia infection caused by inhaling of Legionella species. Long periods of water stagnation should be avoided; it
means the water heater should be used or  ushed at least weekly.
The European standard CEN/TR 16355 gives recommendations for good practice concerning the prevention of Le-
gionella growth in drinking water installations but existing national regulations remain in force.
This electronic storage water heater is sold with a thermal disinfection cycle function enabled by default. Every time
the product is switched on and every 30 days, the thermal disinfection cycle run to heat the water heater up to 60°C.
Warning: when this software has been carrying out the thermal disinfection treatment, water temperature can cause
burns. Feel water before bathing or showering.
TECHNICAL CHARACTERISTICS
For the technical speci cations, refer to the nameplate (the nameplate is located next to the water intake/outlet pipes).
Table 1 - Product information
Product range 50 80 100
Weight (kg) 17 22 26
Installation
Vertical Horizontal Vertical Horizontal Vertical Horizontal
Model Refer to the nameplate
SMART X -- XXXX
Qelec (kWh) 6,893 -- 7,323 7,113 7,455 7,249
Qelec, week, smart (kWh) 24,558 -- 25,435 25,552 26,002 25,879
Qelec, week (kWh) 29,678 -- 32,942 33,330 33,778 34,823
Load pro le M -- MMMM
L
wa
15 dB
wh
40,0% -- 40,0% 40,0% 40,0% 40,0%
V40 (L) 65 -- 92 87 130 103
Capacity (l) 49 75 95
The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure A to this
manual) are de ned in relation to EU Directives 812/2013 and 814/2013.
The products without the label and the data sheet for water heaters and solar devices, stipulated in regulation 812/2013,
are not intended to be used in such assemblies.
The device is equipped with a smart function that allows you to adapt the consumption to the user pro les. If operated
correctly, the device has a daily consumption of “Qelec* (Qelec,week,smart/Qelec,week)” less than that of an
equivalent
product with no smart function.
This appliance is conforming with the international electrical safety standards IEC 60335-1 and IEC 60335-2-21.
The CE marking of the appliances attests its conformity to the following EC Directives, of which it satis es the
essential requisites:
- LVD Low Voltage Directive: EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106.
- EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3.
- RoHS2 Risk of Hazardous Substances: EN 50581.
- ErP Energy related Products: EN 50440.
This product is in conformity with REACH regulations.