Technical information

40
6.5.2. REMOVING THE SAFETY VALVE
(ECOCOMBI 27 MFFI)
1. Remove the U-clip ā€œZā€ (Fig. 6.47);
2. Unscrew and remove the valve (Fig. 6.48).
6.5 ACCESS TO THE WATER CIRCUIT
FIG. 6.48
6.5.1. R
EMOVING THE
D.H.W. (SECONDARY)
E
XCHANGER
1. Remove the screws ā€œYā€ (FIG. 6.44);
3. Push the exchanger towards the rear of the boiler, lift
upwards and remove from the front of the boiler (F
IG.
6.45 - 6.46);
4. Before replacing the exchanger ensure that the O-
rings are in good condition and replace if necessary.
Important! Before any component is removed, the boiler
must be drained of all water.
FIG. 6.46
FIG. 6.47
Y
Y
FIG. 6.44
F
IG. 6.45
Z