6.5.7. REMOVING THE PUMP (ECOSYSTEM 27 RFFI)
1. Unplug the electrical connection “B5” (FIG. 6.72);
2. Remove the U-clip “B6” (FIG. 6.73);
3. Remove the slide plate “B7” (FIG. 6.74);
4. Unscew the screw “B8” under the boiler (F
IG
. 6.75);
5. Remove the U-clip “B9” of the pressure gauge (FIG. 6.76);
6. Remove the pump (FIG. 6.77).