Installation and Use

95
GB
Supplier’s model identi er SGA CA
Model 120 150 200
Certi cate CE
51CL3938
Nominal capacity I 120 150 200
Real capacity I 115 155 195
Nominal pressure bar 8 8 8
Nominal heat rating kW 7,5 8,4 10,1
Useful rating kW 6,4 7,2 8,6
Heating time for DHW t 45°C min. 63 73 73
Heat loss at 60° Celsius W 260 300 330
Hot water ow rate
supply at 30K I/h 182 205 245
supply at 45K l/h 121 136 163
Erp
Declared Load pro le L L XL
Water heating e ciency ηwh % 54,5 55,7 59,7
Water Heating e ciency class B B B
Daily electricity consumption Q
elec
kWh -- -- --
Daily fuel consumption Q
fuel
kWh 24,277 23,728 35,808
Sound power level LWA L
WA
dB 55 55 55
Emissions of nitrogen oxides [mg/kWh] 143 143 154
Annual electricity consumption AEC kWh/annum -- -- --
Annual fuel consumption AFC GJ/annum 17 17 25
Mixed water at 40°C V40 l 177 215 271
Set-point temperature “out of the box” °C 60 60 60
Thermostat temperature settings 5 5 5
Gas supply pressure
G20 Methane mbar 20 20 20
G30 Butane LPG mbar 28 ÷ 30 28 ÷ 30 28 ÷ 30
G31 Propane LPG mbar 37 37 37
gas consumption
G20 Methane m3/h 0,794 0,889 1,069
G30 Butane LPG Kg/h 0,591 0,662 0,795
G31 Propane LPG Kg/h 0,583 0,652 0,784
Combustion gas values
Draught mbar 0,015 0,015 0,015
Flue gas ow rate g/sec 5,4 5,4 7,3
Flue gas temperature °C 172 186 208
For the list of equivalent models refer to Annex A, an integral part of this booklet.
The products without the label and its board for sets of heaters and solar devices, provided for in Regulation 812/2013,
are not intended for use in such sets.