Operating instructions

36
Servicing Instructions
1. Disconnect electrical connections “O” and silicone pipe “P”
(FIG.10.25);
2. Remove screw “Q” and remove the fan collar clamp “R” (FIG.
10.26);
3. Remove screws “S” (F
IG. 10.27);
4. Remove fan and mounting plate (FIG. 10.28).
10.3.6 Removing the fan
FIG. 10.25
O
O
P
FIG. 10.26
Q
R
FIG. 10.27
S
S
S
FIG. 10.28
10.4.1. Removing the spark generator
1. Disconnect ignition leads “T” by pulling upward
(F
IG. 10.29);
2. Remove the screw “U” (FIG. 10.30);
3. Remove the spar k generator by pulling forward from the gas
valve (FIG. 10.31).
FIG. 10.29
FIG. 10.30
FIG. 10.31
T
U
10.4 Access to the Gas Valve