Operating instructions
37
Servicing Instructions
FIG. 10.32
V
10.4.2 Removing the gas valve
Important! Before removing the gas v alve, ensure the gas sup-
ply is turned off.
1. Disconnect all the cables from the solenoid and modureg;
2. Remove the spark generator (see previous section);
3. Release the nuts “V” (F
IG. 10.32);
4. Remove the screws “W” from the bottom of the gas valve (F
IG.
10.33);
5. Remove the gas valve (FIG. 10.34).
V
FIG. 10.33
W
W
FIG. 10.34
10.5 Access to the Water Circuit
FIG. 10.35
X
X
FIG. 10.36
FIG. 10.37
Important! Before any component is remo ved, the boiler
must be drained of all water.
10.5.1 Removing the D.H.W. (secondary) exchanger
1.Remove the screws “X” (F
IG 10.35);
2.Disconnect the cable “Y” (FIG 10.36);
3.Push the exchanger towards the rear of the boiler , and
lift upwards
and remove out of the front of the boiler
(FIG 10.37-10.38);
4.Before replacing the exchanger ensure that the O-rings
are in good condition and replace if necessar y.
Y