Servicing Instructions
10.5.10 Removing the D.H.W. temperature
sensor (N.T.C.)
1. Pull off the electrical connector and unscrew the sensor probe
using a suitable spanner (FIG. 10.57).
FIG. 10.57
FIG. 10.58
FIG. 10.59
J1
K1
10.5.11 Removing the D.H.W. flow switch
1. Unplug the electrical connector “J1” (FIG. 10.58);
2. Unscrew the screws “K1” (F
IG. 10.59);
3. Remove the D.H.W. flow switch.
6.5.12 Removing the divertor valve actuator
1. Unplug the electrical connector “L1” (FIG. 6.60);
2. Release the retaining clip “M1” and remove the divertor
valve actuator (F
IG. 6.61).