Service manual

Indesit Company
12 of 19
Service Manual UK English
Reversing Timer Sequence Chart
Switch Ratings
CONTACT / TERMINAL
RATING COMPONENT
SWITCHED
MAX.
CURRENT
Invensys EC
C3 - C2 16(4)A TIMER MOTOR <1A
C3 - C1 16(4)A TIMER MOTOR <1A
A1 - A3/A4 16(4)A MOTOR & HEATER 10A
B3/B4 - B1 16(4)A HEATER 9.2A
3
140 mins
130 mins
120 mins
110 mins
100 mins
90 mins
80 mins
70 mins
60 mins
50 mins
40 mins
30 mins
20 mins
7.5 mins
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
2.5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
5 min
2.5 min
2.5 min
2.5 min
Auto
C3 - C1 (C3 - C4)
Timed
C3 - C2 (C3 -C5)
stat select
A9 - A11 (A1 - A2)
*1 *1 *1
*1
Timer & Motor
A1 - A3 (B3 - B4)
Buzzer
B10 - B11 (B2 - B1)
Heater
B3 - B1 (A4 - A5)
Note *1: the programme cam should advance to the next step before the timer stops
Main Timer
Sequence Chart
switch
switch
no.
1 2 3 4 5 6 7 8 9 10 1112 13 14 15 16 17 18 19 2021222324252627282930313233343536373839404142434445464748495051525354555657585960
1 to 2 secs - > < - - - - - - - 148 seconds +/-2 - - - - - - - - - - - >: < - 1 to 2 seconds
motor cw a - a1
motor acw a - a0
<------------------------300 seconds--------------------------->